Model |
SW380T |
Head |
360° rotatable Binocular Siedentopf |
Inclination |
30° |
Eyepieces |
Wide-field 10X and 25X pairs |
Interpupillary distance |
48-75mm |
Diopter adjustment |
On left tube, +/-5dp |
Nosepiece |
Quadruple revolving |
Objectives |
Achromatic 4X, NA 0.1, working distance 37.5mm 10X, NA 0.25, working distance 6.54mm 40X(Spring), NA 0.65, working distance 0.63mm 100X (Spring, Oil), NA 1.25, working distance 0.195mm |
Magnifications |
40X, 100X, 250X, 400X, 1000X and 2500X |
Stage |
Double-layered mechanical stage with slide holder |
Stage size |
130mmx130mm |
Stage X-Y range |
70mmx30mm |
Upper limit stop |
Rack stop preset but adjustable |
Condenser |
NA 1.25 with iris diaphragm, swing-in and swing-out filter holder |
Focusing |
Coaxial coarse and ultra-fine focusing system |
Fine focus precision |
3.4µm increments |
Illumination |
Built-in 1W LED transmitted illumination with intensity control |
Power |
110-240V, built-in transformer |




Assembly and set up
Carefully remove the microscope body from the box and set it on a sturdy, flat surface. Delicately remove the microscope head from its packaging, securing it to the body with the designated head locking screw, taking care to avoid overtightening. locking screw, using care not to overtighten.
Gently remove the protective plastic covers from the eyepiece holders located on the microscope's head, then insert the eyepieces into the holders. At this point, you may opt to insert the eyepiece adapter into the trinocular camera port on the top of the microscope and place either a third eyepiece into it or mount an eyepiece camera (not included). Next, locate the power adapter and connect it to the microscope, then plug it in. Activate the microscope by pressing the power button on the rear of the base.
Using the microscope
Power the microscope on and utilize the illumination intensity control wheel to set the lamp on the lowest brightness setting.
Clip a slide into the slide holder on the stage. Use the X-Y translational control knobs on the right side of the stage to move the stage front to back or the slide holder left to right to center the specimen over the bulb.
Move the binocular eyepieces closer together or further apart until you see one image when you look through them. Effortlessly adjust the bulb brightness to a comfortable intensity with the intuitive dimmer wheel. Note that another user can simultaneously appreciate the image through using an eyepiece with the trinocular port.
Always begin with the lowest power objective lens, specifically the 4X objective, centered over the stage. Gaze through the eyepieces and bring the image into focus by gradually turning the larger coarse adjustment focus knob to move the stage closer to the objective. Once a sharp image forms, transition to the blue fine adjustment focus knob to fine-tune for impeccable clarity or to delve into various layers of the specimen under examination. You may also use the diopter adjustment control on the eyepiece holder at this time to further
fine-tune image clarity. Explore other parts of the slide by utilizing the X-Y translational control knobs to move the slide holder once the specimen is in focus.
Elevate magnification by rotating the nosepiece clockwise to a higher magnification objective, ensuring not to strike the slide with the objective, as this may potentially damage the glass on the slide, the objective, or both. If you cannot move the objective into place without making contact with the slide, gracefully use the coarse focus knob to gently move the stage down and away to create ample space before changing magnification.
Delicately adjust the focusing ring on the iris aperture diaphragm to finely alter the resolution of the image, ensuring the clearest view. The condenser can be seamlessly moved closer to or farther from the stage by rotating the metal knob.
For optimal clarity with the 100X objective, use the superior immersion oil provided. Elegantly rotate the nosepiece until the 100X objective is adjacent, but not resting on the specimen slide. Then, place a drop of the included immersion oil onto the cover slip. Slowly rotate the 100X objective into place ensuring it makes contact with the immersion oil. Refine the focus until your specimen is vividly clear. (Note: Immediately after use, meticulously wipe the oil from the objective lens and the cover slip using lens paper moistened with a touch of ethyl or isopropyl alcohol. Remember, do not use immersion oil with the 4X, 10X, or 40X objectives.)
The swing-in and swing-out filter holder is conveniently located at the base of the Abbe condenser. Swing it out and place a 32mm diameter filter, ensuring it remains free of dust, dirt, and fingerprints, thereby maintaining a pristine field lens.
Mounting a camera attachment
Place the eyepiece adapter into the trinocular camera port on the top of the microscope and mount an eyepiece camera (not included) directly on it. If you would like to use a C- mount camera (not included), unscrew the top ring from the eyepiece adapter. You can then use it as a 1X C-mount for the camera.
The parfocality between the eyepieces and the trinocular port has been preset before shipment and should not need adjustment. If necessary, however, you can rotate the parfocal ring in the eyepiece adapter to adjust the adapter height position and resulting parfocality.
Warranty information and customer support
Our microscopes are manufactured to meet ISO 9001 standards. Warranties are as follows:
Five (5) Year Warranty for Microscopes: Microscopes come with a five (5) year warranty against manufacturing defects. Does not cover normal wear, routine maintenance, add-on accessories, damage resulting from repair by unauthorized parties, accident, alteration, shipping, misuse or abuse is not covered.
One (1) Year Warranty for Electrical and Video components. Does not cover light bulbs, batteries, fuses, or electrical cords.
All warranties start from the original date of purchase. We provides the repair or
replacement of warrantied parts for free, including labor, during the warranty period.
Proof of original purchase is required. Buyers are responsible for shipping to and from
our warehouse for warranty services. The warranty does not cover damages resulting
from normal wear and tear, abuse, or unauthorized repairs.
Disclaimer: We are constantly working to improve our instruments and to adapt them in response to customer feedback. These improvements occasionally involve small modifications to the mechanical structure and optical design of our microscopes. Therefore, some descriptions, illustrations, and specifications in this instruction manual may vary slightly from the microscope you receive.

Q1: How can I discover the ideal model tailored for my specific application needs?
Share your essential requirements with us, and we will craft a custom-tailored solution that perfectly aligns with your aspirations. Additionally, you are welcome to send us your specimen for a comprehensive proofing evaluation by our skilled engineers, ensuring flawless compatibility and absolute satisfaction.
1) Kindly specify the exact product you envision. Detailed specifications will empower us to provide a personalized recommendation that perfectly meets your unique aspirations and needs.
2) Please describe your current production process. This will enable us to tailor our expert recommendations to seamlessly align with your operational needs, ensuring optimal efficiency and productivity.
3) We cordially encourage you to communicate your budget parameters and ideal timeline with us. This vital information allows us to customize our offerings and delivery timelines to match your specific requirements, ensuring that we surpass your expectations at every opportunity.
Q2: I've received my Educational Microscope with a 360° Rotatable Binocular Head, but I'm having trouble using it. What steps should I take to become familiar with its operation?
Rest easy knowing we provide an extensive instructional video coupled with a detailed English manual, ensuring a seamless installation and user experience with our product. Should you have further queries, our proficient English-speaking engineers stand by online, ready to assist. In addition, we offer localized support in countries like India, Malaysia, Korea, and Spain, with ambitious plans to expand our reach globally, promising unparalleled support wherever you are.
Q3: If my microscope encounters any issues, what steps should I follow?
Enjoy peace of mind with our robust 36-month warranty, a testament to our unwavering dedication to superior product quality. Should any non-human error part defects occur within this period, we pledge to promptly dispatch replacement parts at no cost. Even beyond the warranty, benefit from our ongoing complimentary online support. For parts replacement, our efficient ordering process ensures your microscope remains in peak condition, guaranteeing uninterrupted operation.