S7 Series model specifications
Model Type |
S7-B
|
S7-T
|
Observation head |
Binocular |
Trinocular |
Optical system |
Greenough |
Observation angle |
45° |
Interpupillary adjustment |
54- 76 mm |
Diopter adjustment |
On left and right tubes, +/-5 |
Zoom range |
0.7X-4.5X, standard |
Zoom ratio |
1:6.4 |
Eyepieces |
WF10X/20mm, standard |
Magnification |
7X-45X, standard |
Auxiliary Objective |
0.5X, 2X, optional |
Focusing travel range |
50mm |
Working distance |
100mm, standard |
Illumination options |
Upper incident and bottom LED lights for S7-BL, S7-TL Upper gooseneck and bottom LED lights for S7-BGL, S7-TGL LED ring light for S7-BP, S7-TP, S7-BS, S7-TS, S7-BD, S7-TD |
Camera adapter
|
- |
0.5X C-mount adapter, optional Φ23.2mm eyepiece camera adapter, optional |
Stand options |
Upper incident and bottom transmitted stand Upper gooseneck and bottom transmitted stand Plain stand, Single-arm boom stand, Dual-arm boom stand |
S7 Series optics specifications
Eyepiece |
Standard Configuration |
WD 100mm |
Mag. |
FOV (mm) |
10X (20mm) |
7X |
28.6 |
45X |
4.4 |
Abbreviations:
WD = Working distance
Mag = Magnification
FOV = Field of view
· The S7-BP with plain stand
· The S7-BL with upper incident and bottom transmitted stand
I. Assembling the microscope
To ensure optimal safety and protection during transit, the components for the S7 series microscopes are shipped detached. Carefully open the Styrofoam packaging, ensuring that no components are inadvertently left attached to the packing materials being removed. Keep all packing materials intact until every component is fully identified and verified for a seamless setup.
When handling components, especially optical lenses, it's crucial to avoid touching lens surfaces with bare hands, as fingerprints and grease reduce image clarity.
Make certain that microscope assembly is conducted on a flat, stable surface to maintain stability throughout usage.
II. Using the microscope
Interpupillary adjustment
Adjust the eyepiece tubes until you see a single circular field through both eyepieces, ensuring a cohesive viewing experience. If you notice two distinct circles, the interpupillary distance is too wide; if the circles overlap, the distance is too narrow, necessitating adjustment. The eyepiece tube allows for adaptable interpupillary distance adjustments from 54 to 76mm, accommodating different users.
Focusing the microscope
Achieve perfect focus on the specimen using the dual side focusing knobs. These knobs regulate the microscope's vertical movement via a precise 'rack and pinion' mechanism, with tension adjustments available through the tension knob within the right focusing knob for enhanced precision.
Initially, use the highest magnification setting for focus. If clarity is lacking, adjust the microscope's height on the pole. Secure the height using the locking screw and support collar for safety.
III. Warranty information and customer support
Our microscopes proudly adhere to ISO 9001 standards, ensuring unmatched quality and assurance. Warranties include:
- Five (5) Year Warranty for Microscopes: This warranty covers manufacturing defects but excludes normal wear, maintenance, accessories, unauthorized repairs, accidents, alterations, shipping, misuse, or abuse.
- One (1) Year Warranty for Electrical and Video components, excluding consumables such as bulbs, batteries, fuses, and cords.
All warranties commence from the date of initial purchase, providing peace of mind right from the start.
We offer complimentary repair or replacement of warranted parts, including labor, within the warranty period.
Proof of original purchase is essential to validate warranty claims.
Buyers are responsible for shipping costs for warranty services, to and from our facility. The warranty does not cover damages arising from normal wear, misuse, or unauthorized repairs. from normal wear and tear, abuse, or unauthorized repairs.
Q1: How can I discover the ideal model tailored for my specific application needs?
Share your vital requirements with us, and we'll craft a bespoke solution that perfectly matches your vision. Additionally, feel free to send us your specimen for a comprehensive proofing evaluation conducted by our proficient engineers, ensuring flawless compatibility and unparalleled satisfaction.
1) Please describe in detail the precise product you are envisioning. By providing comprehensive specifications, you empower us to tailor a recommendation that impeccably aligns with your aspirations, ensuring an unparalleled experience that exceeds expectations.
2) We warmly invite you to unveil the nuances of your current production process. By delving into a thorough understanding of your operations, we are poised to deliver customized, expert recommendations that seamlessly integrate with your distinct operational needs, thereby guaranteeing optimal efficiency and productivity. Our unwavering commitment is to be a pivotal contributor to your success story.
3) We are eager to hear about your budget and preferred timeline. This essential information enables us to design personalized offerings and delivery schedules that not only meet your expectations but exceed them, setting the foundation for a flourishing partnership built on mutual success.
Q2: I've received my Educational Microscope with a 360° Rotatable Binocular Head but find it challenging to operate. How can I become more acquainted with its use?
Your purchase includes a valuable instructional video and a meticulously written English manual, both designed to facilitate a seamless installation and exceptional user experience from start to finish. Should any inquiries arise, our team of skilled English-speaking engineers stands ready online to provide assistance. Additionally, we offer localized support in countries like India, Malaysia, Korea, and Spain, with plans for further global expansion in the future.
Q3: If my microscope encounters issues, what should I do to address them?
Rest assured that your investment is safeguarded by our comprehensive 12-month warranty, underscoring our dedication to outstanding product quality. In the event of any non-human error-related defects in parts within this timeframe, we will swiftly replace them at no extra charge. Beyond the warranty, take advantage of our ongoing, complimentary online support. We've simplified the process for acquiring replacement parts, ensuring your microscope remains in top condition, delivering flawless performance.