S7 Series model specifications
Model Type |
S7-B
|
S7-T
|
Observation head |
Binocular |
Trinocular |
Optical system |
Greenough |
Observation angle |
45° |
Interpupillary adjustment |
54- 76 mm |
Diopter adjustment |
On left and right tubes, +/-5 |
Zoom range |
0.7X-4.5X, standard |
Zoom ratio |
1:6.4 |
Eyepieces |
WF10X/20mm, standard |
Magnification |
7X-45X, standard |
Auxiliary Objective |
0.5X, 2X, optional |
Focusing travel range |
50mm |
Working distance |
100mm, standard |
Illumination options |
Upper incident and bottom LED lights for S7-BL, S7-TL Upper gooseneck and bottom LED lights for S7-BGL, S7-TGL LED ring light for S7-BP, S7-TP, S7-BS, S7-TS, S7-BD, S7-TD |
Camera adapter
|
- |
0.5X C-mount adapter, optional Φ23.2mm eyepiece camera adapter, optional |
Stand options |
Upper incident and bottom transmitted stand Upper gooseneck and bottom transmitted stand Plain stand, Single-arm boom stand, Dual-arm boom stand |
S7 Series optics specifications
Eyepiece |
Standard Configuration |
WD 100mm |
Mag. |
FOV (mm) |
10X (20mm) |
7X |
28.6 |
45X |
4.4 |
Abbreviations:
WD = Working distance
Mag = Magnification
FOV = Field of view
·The S7-BP with plain stand
·The S7-BL with upper incident and bottom transmitted stand
I. Assembling the microscope
The components for the S7 series microscopes are shipped detached for protection. Carefully open the Styrofoam packaging, ensuring that no components are inadvertently left attached to the packing materials being removed. Retain all packing materials until every component has been fully identified and verified.
When handling components, especially optical lenses, it's crucial to avoid touching lens surfaces with bare hands, as fingerprints and grease reduce image clarity.
Ensure that microscope assembly is performed on a flat, secure surface to guarantee stability during usage.
II. Using the microscope
Interpupillary adjustment
Adjust the eyepiece tubes until you see a single circular field through both eyepieces, ensuring a cohesive viewing experience. If two distinct circles are visible, the interpupillary distance is excessive; if overlapping circles appear, the distance is insufficient, indicating the need for adjustment. The eyepiece tube offers adaptable adjustment of interpupillary distance from 54 to 76mm to suit various users.
Focusing the microscope
Focus on the specimen using the dual side focusing knobs. These knobs adjust the microscope's vertical movement via a precise 'rack and pinion' mechanism. Tension adjustments can be made with the tension knob within the right focusing knob.
Initially, use the highest magnification setting to focus. If the specimen remains unclear, adjust the microscope's height on the pole. Always secure the height with the locking screw and support collar afterwards.
III. Warranty information and customer support
Our microscopes proudly adhere to ISO 9001 standards, ensuring unmatched quality and assurance. Warranties include:
- Five (5) Year Warranty for Microscopes: Coverage includes manufacturing defects but excludes normal wear, maintenance, accessories, unauthorized repairs, accidents, alterations, shipping, misuse, or abuse.
- One (1) Year Warranty for Electrical and Video components. Excludes consumables like bulbs, batteries, fuses, and cords.
All warranties commence from the date of initial purchase, providing peace of mind right from the start.
We offer complimentary repair or replacement of warranted parts, including labor, within the warranty period.
Proof of original purchase is essential to validate warranty claims.
Buyers handle shipping costs for warranty services, both to and from our facility. The warranty excludes damages from standard wear, misuse, or unauthorized fixes. from normal wear and tear, abuse, or unauthorized repairs.
Q1: How can I discover the ideal model tailored for my specific application needs?
Share your vital requirements with us, and we'll design a bespoke solution that perfectly matches your vision. Additionally, feel free to send us your specimen for an exhaustive proofing evaluation by our adept engineers, ensuring flawless compatibility and exceptional satisfaction.
1) To ensure your vision becomes a reality, we kindly ask you to detail the precise product specifications you have in mind. By doing so, we can offer recommendations that not only meet but transcend your aspirations, providing you with an unparalleled experience.
2) We warmly invite you to share the intricacies of your current production process with us. With a profound understanding of your operations, we can deliver tailored, expert recommendations that seamlessly integrate with your unique requirements, ensuring unrivaled efficiency and productivity. We are committed to becoming a pivotal part of your success story.
3) We would be thrilled to learn about your budget and preferred timeline. This vital information enables us to tailor bespoke offerings and delivery schedules that not only meet but significantly surpass your expectations, paving the way for a thriving partnership.
Q2: I've received my Educational Microscope with a 360° Rotatable Binocular Head but find it challenging to operate. How can I become more acquainted with its use?
Each purchase is accompanied by a priceless instructional video and a meticulously crafted English manual, designed to ensure a seamless installation and an extraordinary user experience from start to finish. Should questions arise, our proficient English-speaking engineers are readily available online, eager to assist. Additionally, we offer localized support in countries like India, Malaysia, Korea, and Spain, with ambitious plans for future global expansion.
Q3: If my microscope encounters issues, what should I do to address them?
Rest assured, your investment is protected by our comprehensive 12-month warranty, reflecting our unwavering commitment to outstanding product quality. Should any non-human error-related defects in parts arise within this period, we will swiftly replace them at no additional cost. Beyond the warranty, take advantage of our ongoing, complimentary online support. We've simplified the process for ordering replacement parts, ensuring your microscope operates at peak performance, delivering flawless results.