S7 Series model specifications
Model Type |
S7-B
|
S7-T
|
Observation head |
Binocular |
Trinocular |
Optical system |
Greenough |
Observation angle |
45° |
Interpupillary adjustment |
54- 76 mm |
Diopter adjustment |
On left and right tubes, +/-5 |
Zoom range |
0.7X-4.5X, standard |
Zoom ratio |
1:6.4 |
Eyepieces |
WF10X/20mm, standard |
Magnification |
7X-45X, standard |
Auxiliary Objective |
0.5X, 2X, optional |
Focusing travel range |
50mm |
Working distance |
100mm, standard |
Illumination options |
Upper incident and bottom LED lights for S7-BL, S7-TL Upper gooseneck and bottom LED lights for S7-BGL, S7-TGL LED ring light for S7-BP, S7-TP, S7-BS, S7-TS, S7-BD, S7-TD |
Camera adapter
|
- |
0.5X C-mount adapter, optional Φ23.2mm eyepiece camera adapter, optional |
Stand options |
Upper incident and bottom transmitted stand Upper gooseneck and bottom transmitted stand Plain stand, Single-arm boom stand, Dual-arm boom stand |
S7 Series optics specifications
Eyepiece |
Standard Configuration |
WD 100mm |
Mag. |
FOV (mm) |
10X (20mm) |
7X |
28.6 |
45X |
4.4 |
Abbreviations:
WD = Working distance
Mag = Magnification
FOV = Field of view
·The S7-BP with plain stand
·The S7-BL with upper incident and bottom transmitted stand
I. Assembling the microscope
The components for the S7 series microscopes are shipped detached for protection. Carefully open the Styrofoam packaging, ensuring that no components are inadvertently left attached to the packing materials being removed. Retain all packing materials until every component has been fully identified and verified.
When handling components, especially optical lenses, it's crucial to avoid touching lens surfaces with bare hands, as fingerprints and grease reduce image clarity.
Ensure that microscope assembly is performed on a flat, secure surface to guarantee stability during usage.
II. Using the microscope
Interpupillary adjustment
Adjust the eyepiece tubes until you see a single circular field through both eyepieces, ensuring a cohesive viewing experience. If two distinct circles are visible, the interpupillary distance is excessive; if overlapping circles appear, the distance is insufficient, indicating the need for adjustment. The eyepiece tube offers adaptable adjustment of interpupillary distance from 54 to 76mm to suit various users.
Focusing the microscope
Focus on the specimen using the dual side focusing knobs. These knobs adjust the microscope's vertical movement via a precise 'rack and pinion' mechanism. Tension adjustments can be made with the tension knob within the right focusing knob.
Initially, use the highest magnification setting to focus. If the specimen remains unclear, adjust the microscope's height on the pole. Always secure the height with the locking screw and support collar afterwards.
III. Warranty information and customer support
Our microscopes proudly adhere to ISO 9001 standards, ensuring unmatched quality and assurance. Warranties include:
- Five (5) Year Warranty for Microscopes: Coverage includes manufacturing defects but excludes normal wear, maintenance, accessories, unauthorized repairs, accidents, alterations, shipping, misuse, or abuse.
- One (1) Year Warranty for Electrical and Video components. Excludes consumables like bulbs, batteries, fuses, and cords.
All warranties commence from the date of initial purchase, providing peace of mind right from the start.
We offer complimentary repair or replacement of warranted parts, including labor, within the warranty period.
Proof of original purchase is essential to validate warranty claims.
Buyers handle shipping costs for warranty services, both to and from our facility. The warranty excludes damages from standard wear, misuse, or unauthorized fixes. from normal wear and tear, abuse, or unauthorized repairs.
Q1: How can I discover the ideal model tailored for my specific application needs?
Share your vital requirements with us, and we'll design a bespoke solution that perfectly matches your vision. Additionally, feel free to send us your specimen for an exhaustive proofing evaluation by our adept engineers, ensuring flawless compatibility and exceptional satisfaction.
1) Kindly articulate the precise product you envision. By offering detailed specifications, you enable us to provide a recommendation that perfectly fulfills your aspirations, ensuring a matchless experience.
2) We warmly invite you to share the intricacies of your current production process with us. By gaining a comprehensive understanding of your operations, we are equipped to offer bespoke, expert recommendations that harmonize flawlessly with your unique operational requirements, thus ensuring optimal efficiency and productivity. Our commitment is to be an integral part of your success narrative.
3) We would be thrilled to learn about your budget and preferred timeline. This pivotal information empowers us to craft bespoke offerings and delivery schedules that do more than merely meet your expectations-they exceed them, paving the way for a prosperous partnership.
Q2: I've received my Educational Microscope with a 360° Rotatable Binocular Head but find it challenging to operate. How can I become more acquainted with its use?
Each purchase includes an invaluable instructional video and a meticulously crafted English manual, both dedicated to ensuring a seamless installation and an extraordinary user experience from beginning to end. Should any questions arise, our team of proficient English-speaking engineers is readily available online, eager to provide assistance. Furthermore, we extend localized support in countries such as India, Malaysia, Korea, and Spain, with ambitious plans for a global expansion in the future.
Q3: If my microscope encounters issues, what should I do to address them?
Be assured that your investment is well-protected by our extensive 12-month warranty, a testament to our commitment to exceptional product quality. Should any non-human error-related defects in parts occur within this period, we will promptly replace them at no additional cost. Beyond the warranty, you can take advantage of our continuous, complimentary online support. We've streamlined the process for ordering replacement parts, guaranteeing that your microscope remains in peak operational condition, delivering flawless performance.